Browse reports

Every report here was inspected on the property shown and listed by someone who confirmed they hold the right to resell it.

15 reports

Exterior of 23 Thorniley St, New Britain, CT
Home

23 Thorniley St

New Britain, CT 06051

Beds
6
Baths
3
Sq ft
3,000

61-page inspection by Premier Home Inspection, LLC (inspector James Enowitch), performed 14 September 2026 on this 1919 multi-family. Covers exterior, roofing, garage, kitchen, interior rooms, basement and lower level, heating and central air, electrical, plumbing and attic, with photographs and the inspector's notes throughout. The full document, including every finding and photo, downloads immediately after purchase.

Inspected Sep 14, 2026

10 sections covered

$500

one-time

Exterior of 2244 Sycamore Hill Ln, Pittsburgh, PA
HomeDemo

2244 Sycamore Hill Ln

Pittsburgh, PA 15216

Beds
3
Baths
2.5
Sq ft
1,440

End-unit townhouse, 41 pages. Roof is shared with the neighboring unit and was replaced in 2020; the flat section over the entry has ponding after heavy rain. Noted: moisture at the basement party wall below grade, with efflorescence but no active weeping; sump pump cycled correctly on test.

Inspected Sep 11, 2025

10 sections covered

$99

one-time

Exterior of 1208 Saguaro Bloom Ct, Gilbert, AZ
HomeDemo

1208 Saguaro Bloom Ct

Gilbert, AZ 85298

Beds
4
Baths
3
Sq ft
2,760

Newer construction, 71 pages with thermal imaging on every exterior wall. Two-stage HVAC with a 2019 air handler and both condensers running within spec. Noted: one drip leg missing at the water heater gas connection, and a hairline stucco crack above the east garage corner with no moisture reading behind it.

Inspected Aug 19, 2025

11 sections covered

$189

one-time

Exterior of 902 W Kiowa St Unit 4B, Colorado Springs, CO
HomeDemo

902 W Kiowa St Unit 4B

Colorado Springs, CO 80905

Beds
2
Baths
2
Sq ft
1,120

Interior-only condo inspection, 34 pages, since the HOA maintains the envelope. In-unit water heater is a 2021 electric unit with a clean pan. Noted: hall bath exhaust terminates into the attic rather than outside, and the kitchen GFCI at the island would not trip under test.

Inspected Jul 2, 2025

8 sections covered

$89

one-time

Exterior of 2810 Coral Vista Ln, Cape Coral, FL
HomeDemo

2810 Coral Vista Ln

Cape Coral, FL 33991

Beds
3
Baths
2
Sq ft
1,860

Includes wind mitigation detail, which most Florida insurers now ask for. Roof is a 2019 dimensional shingle with a valid permit record. Impact windows throughout. Noted: water staining at the base of the lanai slider, and the irrigation timer did not respond at the panel.

Inspected Jun 4, 2025

11 sections covered

$129

one-time

Exterior of 5629 Dogwood Creek Rd, Raleigh, NC
HomeDemo

5629 Dogwood Creek Rd

Raleigh, NC 27606

Beds
3
Baths
2.5
Sq ft
2,050

55-page report including a crawlspace moisture map. Vapor barrier is intact with one loose section near the rear pier. HVAC is a 2018 heat pump with an aux strip; temperature split measured within range. Noted: deck ledger is fastened with lag bolts but is missing two carriage bolts at the outer band.

Inspected May 8, 2025

11 sections covered

$119

one-time

ElectricalDemo

1840 Whitlock Ave

Marietta, GA 30060

Beds
4
Baths
2.5
Sq ft
2,240

Full electrical inspection with the panel cover removed and every receptacle tested. 200-amp service, one double-tapped breaker, no GFCI protection at either bath, and aluminium branch wiring on the 1978 addition circuit. Each defect photographed with the panel legend transcribed.

Inspected May 6, 2025

4 sections covered

$165

one-time

Termite / PestDemo

515 S Willow Ave

Tampa, FL 33606

Beds
3
Baths
2
Sq ft
1,720

Wood-destroying organism inspection on the form Florida lenders accept. No live activity found. Old gallery damage at the rear sill plate, a previous treatment sticker at the east wall dated 2016, and one section of soil contact above the slab. Treatment and re-inspection options priced on the last page.

Inspected Apr 30, 2025

4 sections covered

$85

one-time

RadonDemo

212 Wheatfield Ln

Lititz, PA 17543

Beds
4
Baths
2.5
Sq ft
2,680

48-hour charcoal canister test in the finished basement, closed-house conditions. Result 4.2 pCi/L against the EPA action level of 4.0, so mitigation is recommended. The report names the lab, the placement diagram, the chain-of-custody form and a suggested sub-slab depressurisation quote.

Inspected Apr 8, 2025

4 sections covered

$95

one-time

ChimneyDemo

3312 Bridge Ave

Cleveland, OH 44113

Beds
6
Baths
3
Sq ft
3,120

Masonry chimney on a 1921 double, swept and photographed from the roof and the firebox. Crown cracked on the north side, two spalled bricks at the cap, and a gap in the clay tile liner at the second joint. Damper operable. Liner repair quoted; sweep certificate included.

Inspected Mar 27, 2025

4 sections covered

$145

one-time

Exterior of 4417 Bluebonnet Ridge Dr, Austin, TX
HomeDemo

4417 Bluebonnet Ridge Dr

Austin, TX 78745

Beds
4
Baths
2.5
Sq ft
2,140

Full 10-section residential inspection, 62-page report with 84 photos. Roof covering is architectural shingle, roughly 12 years old, with minor granule loss on the south slope. HVAC is a 2016 gas furnace with a matching condenser; both operating within normal range at time of inspection. Noted: hairline cracking at two window corners in the front bedroom, and a slow drain at the hall bath.

Inspected Mar 12, 2025

10 sections covered

$149

one-time

Sewer ScopeDemo

708 Oberlin Rd

Raleigh, NC 27605

Beds
3
Baths
2
Sq ft
1,980

Camera run from the rear cleanout 78 feet to the city main in 4-inch cast iron. Root intrusion at 41 feet, an offset joint at 63 feet, and standing water at the trap. Video file and still frames included; a spot repair at 41 feet was quoted separately.

Inspected Feb 19, 2025

4 sections covered

$125

one-time

Structural / FoundationDemo

4621 Kingston Pike

Knoxville, TN 37919

Beds
4
Baths
3
Sq ft
2,540

Engineer's foundation and framing report on a crawlspace house. Stair-step cracking at the northwest corner with about half an inch of deflection over eight feet, three shimmed piers, and no active moisture at the time of inspection. Recommendations set out in order of urgency, with a repair budget range.

Inspected Jan 23, 2025

4 sections covered

$225

one-time

Exterior of 7734 Maple Grove Ave, Columbus, OH
HomeDemo

7734 Maple Grove Ave

Columbus, OH 43235

Beds
3
Baths
1.5
Sq ft
1,520

Solid mid-century ranch, 48 pages. Original cast-iron drain line has been partially replaced with PVC at the main stack; the remaining section under the slab was scoped on camera and is clear. Furnace is 2009, serviced annually. Noted: attic insulation is below current code depth and the garage door opener needs a new safety reverse adjustment.

Inspected Jan 22, 2025

10 sections covered

$99

one-time

Exterior of 3415 Alder Point Way, Tacoma, WA
HomeDemo

3415 Alder Point Way

Tacoma, WA 98407

Beds
3
Baths
2
Sq ft
1,680

Older home with a full sewer scope included. Sewer line is original clay, scoped clean to the main with one minor offset at 41 feet. Roof is a 2014 composition shingle with a valley repair. Noted: galvanized supply lines have been mostly replaced, with two short runs remaining at the laundry; foundation is post-and-pier with no visible movement.

Inspected Nov 14, 2024

11 sections covered

$109

one-time